Farwest Paint Manufacturing Co.
4522 South 133rd Street
Tukwila, Washington, 98168
http://www.farwestpaint.com
Sections I-IV (This Page) / Sections V-X (Click Here)
Material Safety Data Sheet
For Coatings and Related Materials
Prep: Oct. 1990 Update: Apr. 1992
 
Section I  - Product Identification
24 Hour Emergency Assistance
Emergency (Chemtrec) (800) 424-9300
Information  (Farwest) (206) 244-8844
Product Number: 100

Product Name: Flat Alkyd Enamel

Product Class: Pigmented, Modified Alkyd Resin Solution

   Hazard Rating
           0             Lowest
           1                  |
           2                  |
           3                  |
           4           Extreme
This Product
   Health: 1
   Flammability: 2
   Reactivity: 1
   Personal Protection: G

Section II - Hazardous Ingredients

Ingredient CAS Number Percent (By Weight)

Occupational

TLV (ACGIH)

Exposure

PEL (OSHA)

Mineral Spirits 350 8032-32-4 18.51% 100ppm 100ppm
Paraffins (Inc. Naphthenes) 64742-47-8 3.32% 70ppm Not Estab.
Aromatics 64742-95-6 6.45% 70ppm Not Estab.

"Pursuant to Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA) and 40 CFR Part 372, this product contains or may contain a toxic chemical in a quantity subject to the reporting requirements under Section 313"

Section III - Physical Data
Boiling Range: 157-300 F. Weight/Gallon: 12.35 lbs. Vapor Pressure: 7mmHg@20C
Vapor Density: Heavier than Air: XX Lighter than Air:
Evaporation Rate: Faster than Ether: Slower than Ether: XX
Percent Organic Volatile by Volume: 51.48% Solubility in Water: NIL
VOC: 418 Grams/Liter (Less Water) Reactivity in Water: NIL
Appearance: White (or tinted) liquid with slightly sweet aromatic odor.

Section IV - Fire and Explosion Hazard Data

Flammability Classification: OSHA: Combustible Flash Point: 100  F. TCC
Class: 3 LEL: 0.9%   UEL: 6.1%
DOT: Combustible UN Number: 1263
Extinguishing Media: Foam, CO2, Dry Chemical, or Water Fog.
Use the above or any Class B extinguishing agent. Water may be unsuitable as an extinguishing medium, but helpful in keeping adjacent containers cool.
Special Firefighting Procedures: Firefighters and others exposed to vapors or products of combustion should wear self-contained breathing apparatus. Evacuate area of unprotected personnel. Wear protective clothing.
Unusual Fire and Explosion Hazards: Vapors may form an explosive mixture in air and may be ignited by sparks, pilot lights, etc. Closed containers may rupture when exposed to extreme heat.

100 (solvent)