Farwest Paint Manufacturing Co.
4522 South 133rd Street
Tukwila, Washington, 98168
http://www.farwestpaint.com
Sections I-IV (This Page) / Sections V-X (Click Here)
Material Safety Data Sheet
For Coatings and Related Materials
Prep: Nov. 1992 Update: June 2000
 
Section I  - Product Identification
24 Hour Emergency Assistance
Emergency (Chemtrec) (800) 424-9300
Information  (Farwest) (206) 244-8844
Product Number: 1016

Product Name: Aluminum Rust Resistor

Product Class: Metallic, Alkyd Resin Solution

   Hazard Rating
           0             Lowest
           1                  |
           2                  |
           3                  |
           4           Extreme
This Product
   Health: 2
   Flammability: 1
   Reactivity: 2
   Personal Protection: G

Section II - Hazardous Ingredients

Ingredient CAS Number Percent (By Weight)

Occupational

TLV (ACGIH)

Exposure

PEL (OSHA)

Mineral Spirits 8052-41-3 48% 100ppm 100ppm
Xylene 1330-20-7 6% 100ppm 100ppm
Aluminum Flakes 7429-90-5 14% 5mg/m3 5mg/m3

"Pursuant to Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA) and 40 CFR Part 372, this product contains or may contain a toxic chemical in a quantity subject to the reporting requirements under Section 313"

Section III - Physical Data
Boiling Range: 281-389 F. Weight/Gallon: 8.02 lbs. Vapor Pressure: 6.6mmHg@20C
Vapor Density: Heavier than Air: XX Lighter than Air:
Evaporation Rate: Faster than Ether: Slower than Ether: XX
Percent Organic Volatile by Volume: 61%     Solubility in Water: NIL
VOC: 444 Grams/Liter (Less Water) Reactivity in Water: Yes
Appearance: Thin silvery liquid, mild aromatic odor.

Section IV - Fire and Explosion Hazard Data

Flammability Classification: OSHA: Flammable Flash Point: 80  F. TCC
Class: 3 LEL: 0.8%   UEL: 7.0%
Autoignition Temp: 490 F. DOT: Flammable UN Number: 1263
Extinguishing Media: Foam, CO2, Dry Chemical, or Water Fog.
Use the above or any Class B extinguishing agent. Water may be unsuitable as an extinguishing medium, but helpful in keeping adjacent containers cool.
Special Firefighting Procedures: Firefighters and others exposed to vapors or products of combustion should wear self-contained breathing apparatus. Evacuate area of unprotected personnel. Wear protective clothing.
Unusual Fire and Explosion Hazards: Vapors may form an explosive mixture in air and may be ignited by sparks, pilot lights, etc. Closed containers may rupture when exposed to extreme heat. Containers contaminated with water may become explosive due to formation of hydrogen gas from aluminum and water reacting.

1016 (solvent)