- Farwest Paint Manufacturing Co.
- 4522 South 133rd Street
- Tukwila, Washington, 98168
http://www.farwestpaint.com
|
- Material Safety Data Sheet
- For Coatings and Related Materials
- Prep: Dec. 1993 Update: Mar. 1999
-
|
Section I - Product Identification |
- 24 Hour Emergency Assistance
- Emergency (Chemtrec) (800) 424-9300
- Information (Farwest) (206) 244-8844
|
Product Number: 970 Product
Name: Poroseal PVA Primer
Product Class: Vinyl Acrylic Latex Paint |
- Hazard Rating
- 0
Lowest
- 1
|
- 2
|
- 3
|
- 4
Extreme
|
- This Product
- Health: 1
- Flammability: 0
- Reactivity: 0
- Personal Protection: E
|
|
Hazardous Material: Yes:
No: XX |
|
EPA Registration Number (if applicable): N/A |
|
Section II - Hazardous Ingredients |
Ingredient |
CAS Number |
Percent (By Weight) |
Occupational
TLV (ACGIH) |
Exposure
PEL (OSHA) |
Texanol (Ester Alcohol) |
25265-77-4 |
0.70% |
100ppm |
100ppm |
"Pursuant to Title III of the Superfund Amendments and
Reauthorization Act of 1986 (SARA) and 40 CFR Part 372, this product contains or may
contain a toxic chemical in a quantity subject to the reporting requirements under Section
313"
Section III - Physical Data |
Boiling Range: 212 F. |
Weight/Gallon: 10.53 lbs. |
Vapor Pressure: 23.8mmHg@20C |
Vapor Density: |
Heavier than Air: XX |
Lighter than Air: |
Evaporation Rate: |
Faster than Ether: |
Slower than Ether: XX |
Percent Organic Volatile by Volume:
70% |
|
Solubility in Water: Infinite |
VOC: 27 Grams/Liter (Less Water) |
|
Reactivity in Water: None |
Melting Point: Unknown |
pH: 8-9
|
Viscosity: 90 KU |
Freezing Point: 32 F. |
Decomposition Temp: Unknown |
Corrosion Rate: Unknown |
Autoignition Temp: Unknown |
Specific Gravity: 1.2641 |
|
|
Appearance & Odor: Thixotropic liquid with
slight odor; color of tint. |
Section IV - Fire and Explosion Hazard Data
Flammability Classification: |
OSHA: Nonflammable |
Flash Point: N/A |
|
Class: Not Restricted |
LEL: N/A UEL:
N/A |
|
DOT: Nonflammable |
UN Number: N/A |
- U.S. Postal Regulations: Nonflammable, Nonhazardous, OK to ship
by mail.
- Extinguishing Media: Foam, Dry Chemical, Water or Water Fog.
- Special Firefighting Procedures: Water may be used to cool and
protect adjacent containers.
- Unusual Fire & Explosion Hazards: Will not burn; closed
containers may rupture when exposed to extreme heat or fire.
970 (latex)