- Farwest Paint Manufacturing Co.
- 4522 South 133rd Street
- Tukwila, Washington, 98168
http://www.farwestpaint.com
|
- Material Safety Data Sheet
- For Coatings and Related Materials
- Prep: July 1990 Update: Apr. 1999
-
|
Section I - Product Identification |
- 24 Hour Emergency Assistance
- Emergency (Chemtrec) (800) 424-9300
- Information (Farwest) (206) 244-8844
|
Product Number: MIL-P-21035 (A-9-73 & X-6442) Product
Name: Zinc Dust Primer
Product Class: Organic-Inorganic Zinc Rich Primer |
- Hazard Rating
- 0
Lowest
- 1
|
- 2
|
- 3
|
- 4
Extreme
|
- This Product
- Health: 2
- Flammability: 2
- Reactivity: 1
- Personal Protection: H
|
|
Hazardous Material: Yes:
No: XX |
|
EPA Registration Number (if applicable): N/A |
|
Section II - Hazardous Ingredients |
Ingredient |
CAS Number |
Percent (By Weight) |
Occupational
TLV (ACGIH) |
Exposure
PEL (OSHA) |
Toluol |
108-88-3 |
17-19% |
100ppm |
200ppm |
Zinc Dust |
7440-66-6 |
70-71% |
10mg/m3 |
10mg/m3 |
Regular Commercial Grade Zinc Dust may Typically Contain:
- ZnO (2.0%) -TLV-5.0 for freshly formed fumes.
- Pb (.08%) -TLV-0.2
- Cd (.04%) -TLV-0.2 for durst.
"Pursuant to Title III of the Superfund Amendments and
Reauthorization Act of 1986 (SARA) and 40 CFR Part 372, this product contains or may
contain a toxic chemical in a quantity subject to the reporting requirements under Section
313"
Section III - Physical Data |
Boiling Range: 230-232 F. |
Weight/Gallon: 21.8 lbs. |
Vapor Pressure: 2.6mmHg@20C |
Vapor Density: |
Heavier than Air: XX |
Lighter than Air: |
Evaporation Rate: |
Faster than Ether: |
Slower than Ether: XX |
Percent Organic Volatile by Volume:
58% |
|
Solubility in Water: NIL |
VOC: 486 Grams/Liter (Less Water) |
|
Reactivity in Water: NIL |
|
Appearance & Odor: Gray liquid. |
Section IV - Fire and Explosion Hazard Data
Flammability Classification: |
OSHA: Flammable Liquid |
Flash Point: 50 F. TCC |
|
Class: 3 |
LEL:
1.0% UEL: 7.0% |
|
DOT: Flammable Liquid |
UN Number: 1263 |
- Extinguishing Media: Foam, CO2, Dry Chemical, or Water Fog.
- Use the above or any Class B extinguishing agent. Water may be unsuitable as an
extinguishing medium, but helpful in keeping adjacent containers cool.
- Special Firefighting Procedures: Firefighters and others exposed
to vapors or products of combustion should wear self-contained breathing apparatus.
Evacuate area of unprotected personnel. Wear protective clothing.
- Unusual Fire and Explosion Hazards: Vapors may form an explosive
mixture in air and may be ignited by sparks, pilot lights, etc. Closed containers may
rupture when exposed to extreme heat.
MIL-P-21035 (solvent)