Farwest Paint Manufacturing Co.
4522 South 133rd Street
Tukwila, Washington, 98168
http://www.farwestpaint.com
Sections I-IV (This Page) / Sections V-X (Click Here)
Material Safety Data Sheet
For Coatings and Related Materials
Prep: Jan. 1996 Update: Current
 
Section I  - Product Identification
24 Hour Emergency Assistance
Emergency (Chemtrec) (800) 424-9300
Information  (Farwest) (206) 244-8844
Product Number: X-6748

Product Name: Red Lead Replacement Primer

   Hazard Rating
           0             Lowest
           1                  |
           2                  |
           3                  |
           4           Extreme
This Product
   Health: 3
   Flammability: 2
   Reactivity: 0
   Personal Protection: G
Hazardous Material: Yes:        No:  XX
EPA Registration Number  (if applicable): N/A

Section II - Hazardous Ingredients

Ingredient CAS Number Percent (By Weight)

Occupational

TLV (ACGIH)

Exposure

PEL (OSHA)

Mineral Spirits 8032-32-4 50-60% 100ppm 250ppm
Xylene 1330-20-7 1-5% 100ppm 100ppm
Lead (of Chrome Yellow)
Chromate (CR6+ of Ch. Ylw.)
1333-82-0 8% 0.05mg/m3 0.10mg/m3

"Pursuant to Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA) and 40 CFR Part 372, this product contains or may contain a toxic chemical in a quantity subject to the reporting requirements under Section 313"

Section III - Physical Data
Boiling Range: 307-387 F. Weight/Gallon: 12.6 lbs. Vapor Pressure: 2.6mmHg@20C
Vapor Density: Heavier than Air: XX Lighter than Air:
Evaporation Rate: Faster than Ether: Slower than Ether: XX
Percent Organic Volatile by Volume: 55%   Solubility in Water: NIL
VOC: 440 Grams/Liter (Less Water) Decomposition Temp: 500 C. Reactivity in Water: NIL
Appearance & Odor: Orange liquid, mild odor.

Section IV - Fire and Explosion Hazard Data

Flammability Classification: OSHA:Combustible Flash Point: 100 F. TCC
Class: 3 LEL: 0.7%        UEL: 6.0%
DOT: Combustible UN Number: 1263
Extinguishing Media: Foam, CO2, Dry Chemical, or Water Fog.
Use the above or any Class B extinguishing agent. Water may be unsuitable as an extinguishing medium, but helpful in keeping adjacent containers cool.
Special Firefighting Procedures: Firefighters and others exposed to vapors or products of combustion should wear self-contained breathing apparatus. Evacuate area of unprotected personnel. Wear protective clothing.
Unusual Fire and Explosion Hazards: Vapors may form an explosive mixture in air and may be ignited by sparks, pilot lights, etc. Closed containers may rupture when exposed to extreme heat.

X-6748 (solead)