- Farwest Paint Manufacturing Co.
- 4522 South 133rd Street
- Tukwila, Washington, 98168
http://www.farwestpaint.com
|
- Material Safety Data Sheet
- For Coatings and Related Materials
- Prep: Jan. 1985 Update: July 1999
-
|
Section I - Product Identification |
- 24 Hour Emergency Assistance
- Emergency (Chemtrec) (800) 424-9300
- Information (Farwest) (206) 244-8844
|
- Specification No:
National Stock No:
- Product Name: Denatured Alcohol
- CAS # 64-17-5
-
- Product Class: Alcohol Mixture
|
- Hazard Rating
- 0
Lowest
- 1
|
- 2
|
- 3
|
- 4
Extreme
|
- This Product
- Health: 1
- Flammability: 3
- Reactivity: 0
- Personal Protection: G
|
|
- Hazardous Material: Yes: XX No:
- EPA Registration Number (if Applicable): N/A
|
|
Section II - Hazardous Ingredients |
Ingredient |
CAS Number |
Percent (By Weight) |
Occupational
TLV (ACGIH) |
Exposure
PEL (OSHA) |
Ethyl Alcohol |
64-17-5 |
85.00% |
1000ppm |
1000ppm |
Methyl Alcohol, Methanol |
67-56-1 |
4.29% |
200ppm |
200ppm-Skin |
Isopropanol |
67-63-0 |
9.01% |
400ppm |
400ppm |
Methyl-Isobutyl-Ketone |
108-10-1 |
.90% |
50ppm |
50ppm |
ALCOHOLS CONTAINING METHANOL CANNOT BE MADE
NON-POISONOUS.
"Pursuant to Title III of the Superfund Amendments and
Reauthorization Act of 1986 (SARA) and 40 CFR Part 372, this product contains or may
contain a toxic chemical in a quantity subject to the reporting requirements under Section
313"
Section III - Physical Data |
Boiling Range: 170-176 F. |
Weight/Gallon: 6.62 lbs. |
Vapor Pressure: 44mmHg@20C |
Vapor Density: |
Heavier than Air: XX |
Lighter than Air: 1.6 (AIR=1) |
Evaporation Rate: |
Faster than Ether: |
Slower than Ether: XX |
Percent Volatile by Volume: 100% |
pH: N/A |
Solubility in Water: Complete |
VOC: 793 Grams/Liter (Less Water) |
Viscosity: N/A |
Reactivity in Water: None |
Melting Point: N/A |
Freezing Point: N/A |
Decomposition Temp: Not Avail. |
|
Appearance & Odor: Clear, colorless, mild
odor. |
Section IV - Fire and Explosion Hazard Data
Flammability Classification: |
OSHA: Flammable |
Flash Point: 66 F. TCC |
|
Class: 3 |
LEL: 3.3% UEL: 19% |
|
DOT: Flammable |
UN Number: 1170 |
- Extinguishing Media: Foam, CO2, Dry Chemical or Water Fog.
- Use the above or any Class B extinguishing agent. Water may be unsuitable as an
extinguishing medium, but helpful in keeping adjacent containers cool.
- Special Firefighting Procedures: Firefighters and others exposed
to vapors or products of combustion should wear self-contained breathing apparatus.
Evacuate area of unprotected personnel. Wear protective clothing.
- Unusual Fire and Explosion Hazards: Vapors may form an explosive
mixture in air and may be ignited by sparks, pilot lights, etc. Closed containers may
rupture when exposed to extreme heat.
DEN.ALC. (solvent)